The filter prevents solids from penetrating the priming pump, and the non-return valve (H) secures that back flow is avoided when the priming pump is stopped. If the main pump has positive suction head the solenoid valve stops water from running through the priming pump unexpected when the pump and priming pump are stopped. The priming pump is provided with a supplementary tank at the discharge side of the priming pump which has to be filled with water prior to starting the system. During priming, the air escapes while the water circulates in the pump procuring sealing and cooling.
Make | DESMI |
---|---|
Manufacturer | DESMI |
Model code | B114N/60 Hz |
Application | Cooling |
Type | Centrifugal |
Speed | 3410 RPM |
Voltage | 250 ~ 280 V (Delta) / 440 ~ 480 V Y (Star) V |
Additional info |
The filter prevents solids from penetrating the priming pump, and the non-return valve (H) secures that back flow is avoided when the priming pump is stopped. If the main pump has positive suction head the solenoid valve stops water from running through the priming pump unexpected when the pump and priming pump are stopped. The priming pump is provided with a supplementary tank at the discharge side of the priming pump which has to be filled with water prior to starting the system. During priming, the air escapes while the water circulates in the pump procuring sealing and cooling. |