CM Technologies WTK-CT-80045 Rapid Ballast Water Test Kit

Technical Specification

Features:
  • Make: CM Technologies
  • Model code: WTK-CT-80045
  • Kit: Yes
  • Test time: 3 mins
Additional info:

The CMT Rapid Ballast Water Validation Test Kit provides a simple rapid method for determining the efficiency of ballast water treatment systems The kit provides ship operators, Port State Control (PSC), and other compliance officers with a simple, effective tool to assess the risk of discharging ballast water Utilizing three instruments, the CMT Rapid Ballast Water Test Kit satisfies the testing protocol for the D1 standard, allows a user to quickly and easily decide if a system is in gross exceedance of the D2 standard, and provides a simple solution to test total residual oxidant levels in chemical disinfection systems A salinity refractometer provides a simple test to confirm that an exchange occurred A portable, pocket size digital fluorometer tests for photosynthetically active chlorophyll, like that found in living phytoplankton, in less than 3 minutes. This will provide an indication of whether or not the treatment of the ballast water system was effective A waterproof colorimeter tests for Total Residual Oxidant (TRO) with a range of 0 to 5 ppm free & total chlorine in less than 3 minutes Ship operators can easily verify whether the ballast water treatment system has adequately treated water prior to discharge

Make CM Technologies
Manufacturer CM Technologies GmbH
Model code WTK-CT-80045
Kit Yes
Test time 3 mins
Additional info
  • The CMT Rapid Ballast Water Validation Test Kit provides a simple rapid method for determining the efficiency of ballast water treatment systems
  • The kit provides ship operators, Port State Control (PSC), and other compliance officers with a simple, effective tool to assess the risk of discharging ballast water
  • Utilizing three instruments, the CMT Rapid Ballast Water Test Kit satisfies the testing protocol for the D1 standard, allows a user to quickly and easily decide if a system is in gross exceedance of the D2 standard, and provides a simple solution to test total residual oxidant levels in chemical disinfection systems
  • A salinity refractometer provides a simple test to confirm that an exchange occurred
  • A portable, pocket size digital fluorometer tests for photosynthetically active chlorophyll, like that found in living phytoplankton, in less than 3 minutes. This will provide an indication of whether or not the treatment of the ballast water system was effective
  • A waterproof colorimeter tests for Total Residual Oxidant (TRO) with a range of 0 to 5 ppm free & total chlorine in less than 3 minutes
  • Ship operators can easily verify whether the ballast water treatment system has adequately treated water prior to discharge